RV30, 36, 46 Service ManualRVC RVRRaised Vent
RVCPARTS
RVC30, 36, 46REF# PART # DESCRIPTION1 82708A, B, W LEFT END CAP2 82705AS, B, WS TOP CAP, 30" VENT2 82706AS, BS, WS TOP CAP, 36" VENT2 82707A
RVRPARTS
RVR30, 36, 46REF# PART # DESCRIPTION1 82708A, B, W LEFT END CAP2 82705AS, B, WS TOP CAP, 30" VENT2 82706AS, BS, WS TOP CAP, 36" VENT2 82707A
Technical Manual - Page 135RV
Page 1 of 1 Issued By: Technical Service Date Issued: 4-2004 Distribution: Service/Parts Supercedes: Subject: Service I
Theory of OperationWhen keypad up/down button is pushed, contacts on the main PCB close between #12and #13. Closing these contacts activates the triac
If the above test does not show a closed circuit, perform the following.♦ Check for grease or any foreign material between the Touch Buttons and the
Possible FailuresA. Unit dead on arrival1. Check the keypad to be sure that the Lockout Mode has not been activated (lookfor the two LED’s) To disab
2. If the problem can be traced or associated with the use of an electronic gascooktop (of any design) then a filter assembly (part number 86325) sho
If DELAY OFF function is on, this will also be cancelled by pressing the OFF button.DELAY OFF BUTTONThis button has a toggle action. Pressing and rele
THE BUTTONS WILL BE DISABLED UNTIL THIS FUNCTION IS ENABLED BYAGAIN PRESSING AND HOLDING THE TWO SPEED BUTTONS FOR 0.5SECONDS. This function will perm
R V - RAISED VENTRef. Description R V30 R V36 R V461 Top Cap 82740B/R/S 82741B/R/S 82742B/R/S2* End Cap - Left 82997 82997 829973* End Cap - Right 829