Dacor DRT304 Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Cuisiniers Dacor DRT304. ERV3615 - Appliances Connection [en] Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 1
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
PLANNING
GUIDE
CI.10
Specications subject to change without notice. Phone: (800) 793-0093www.Dacor.com
DRT Series Slide-in Cooktop
with ERV Series Slim Raised Vent
COMBINATION INSTALLATIONS
CABINET/COUNTERTOP CUTOUT DIMENSIONS WITH RAISED VENT - TOP VIEW
CABINET/COUNTERTOP CUTOUT DIMENSIONS
WITH RAISED VENT - SIDE VIEW
Document # PGCI-024 Revised 02/03/11 Page 1/1
Model No.
Approved Raised
Vent Model
DRT366S ERV3615
Cutout tolerances: +1/16” (+1.6 mm), -0, unless otherwise stated.
IMPORTANT:
Use only approved raised vent model.
Model DRT304 is not approved for use with a raised
vent.
Use only raised vent model specified. Raised vent
is not compatible with DRT cooktops having a serial
number starting with letters “SA.”
wARNINg
• Observe all governing codes and ordinances during
planning and installation. Contact your local building
department for further information.
• All appliances must be installed in accordance with
the accompanying installation instructions.
Stiffener
Cabinet face
Control panel
Countertop
Use Dacor raised
vent, model
ERV3615 only
IMPORTANT: See raised vent
installation instructions for
duct system layout/planning
DRT366 cooktop
3/8” min. (1.0 cm)
space behind
raised vent
chassis to clear
stiffener
3/8” min. (1.0 cm)
flat countertop
overhang required
behind cutout
Minimum
countertop
height:
30 1/4"
(76.8 cm)
28 5/16” (71.9 cm)
Non combustible rear
wall recommended
10” (2.5 cm) min. to
combustible wall
above countertop,
both sides
Cabinet face
below countertop
overhang
3/8” (1.0 cm) min.
countertop overhang
2 5/8”
(6.7 cm)
Hole 1/2” dia. (1.3 cm),
2 places, through platform
for hold down bolts
1/2” (1.3 cm)
countertop
overhang
1” (2.5 cm) thick mounting platform min.
Open to below to allow for raised
vent, gas and electrical connections
Countertop
Countertop
1/2” (1.3 cm)
countertop
overhang
2” (5.1 cm)
1” (2.5 cm)
15”
(38.1 cm)
24 1/2”
(62.2 cm)
D
E
D
F
B
C
L
B - Cutout
width
D E
F - Raised
Vent Cutout
36”
(91.4 cm)
16 5/8”
(42.2 cm)
11 3/16”
(28.4 cm)
33 1/2”
(85.1 cm)
NOTE: Gas and electrical connections may only
be routed through the bottom of the cooktop when
installed with a raised vent.