Dacor AEHK2CP Manuel d'installation

Naviguer en ligne ou télécharger Manuel d'installation pour Non Dacor AEHK2CP. Dacor AEHK2CP Installation Instructions [1.9 MB] Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 48
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
Installation Instructions
Renaissance
®
Wall Mount Range Hoods
For use with models:
EH30, EH36, EH42, EH48, EH54,
MH30, MH36 and MH48
Part No. 102139 Rev. L
APPROVED FOR USE WITH ALL DACOR
®
RANGES AND COOKTOPS.
TESTED IN ACCORDANCE WITH THE LATEST EDITION OF ANSI/UL 507
STANDARD FOR ELECTRIC FANS AND CAN/CSA-C22.2 NO. 113 STANDARD
FOR FANS AND VENTILATORS.
Vue de la page 0
1 2 3 4 5 6 ... 47 48

Résumé du contenu

Page 1 - Wall Mount Range Hoods

Installation InstructionsRenaissance® Wall Mount Range HoodsFor use with models: EH30, EH36, EH42, EH48, EH54, MH30, MH36 and MH48Part No. 102139 R

Page 2 - Before You Begin

8Electrical Service Installation WARNINGThe electric service to the range hood should be installed only by a licensed electrician.Install a junction b

Page 3 - Important Safety Instructions

9Preparing for InstallationDuct Cut-Out for Rear VentingBack wallDuct Cut-Out for Top VentingCeiling or cabinet bottomInstallation Instructions WARNIN

Page 4

10Installation InstructionsRotating the Blower for Models:EH3012, MH3012, EH3612, MH3612 and EH4212 (Models that are 12 inches high equipped with a si

Page 5

1117. Tip the hood back down so that the top of the hood faces up. Using existing screws, attach the cover plate removed in step 3 to the top of the

Page 6

1210. Remove and discard the mounting plates attached to both blow-er motors.11. Remove the nuts that hold the rear mount-ing plates in place and re

Page 7

1314. Route the wiring harness as shown below. Secure the harness to the motor assemblies using the cable clamps supplied with the hood in the positi

Page 8

14Installation Instructions8. Disconnect the wiring harness connector from the blower motor.9. While supporting the blower from below, remove the fo

Page 9

15Installation InstructionsRotating the Blower for Models:EH4818, MH4818 and EH5418 (Models that are 18 inches high equipped with two blowers.1. Plac

Page 10 - Preparing for Installation

16AHT10 Transition Kit InstallationOn dual exhaust models, the two 8” exhausts may be merged into one 10” duct using Dacor transition kit AHT10. Insta

Page 11

173. Find the temporary mounting bracket in the shipping box. Put the bracket against the wall and line up the center hole with the intersection of t

Page 12

Installation Instructions ... 9Rotating the Blower ...

Page 13

18Installation InstructionsDuct Work Installation WARNINGDuring duct installation, make sure there are no obstructions that keep the damper flaps on t

Page 14

191. Turn off power to the hood electrical circuit at the circuit breaker or fuse box.2. Feed the wiring through the wiring access holes in the hood

Page 15

20Installation Instructions WARNING• Do not ground the circuit to a gas line.• Do not ground the circuit to a hot water pipe.• Water lines that are

Page 16

21Verifying Proper Operation1. Make sure the main power switch is off.2. Turn on power at the circuit breaker panel or fuse box.3. Turn on the main

Page 17

22Wiring DiagramsP3BBBLBLOORRRRWW WWWWWWWWWWW112235 46789101235 467891011354 678910YYWYWYBLOWER455W, 115VHOOD LIGHTS75W, 120V EACHHOOD POWER ANDCONTRO

Page 18

23Wiring DiagramsP3BLOWER455W, 115VBBBBBL BLBLOOOORRRRBBRRWWWW WWWWWWWWWWW112235 46789101235 467891011354 678910WY WYYWBLOWER455W, 115VHOOD LIGHT75W,

Page 19

24Notes

Page 21

Dacor ● 14425 Clark Avenue, City of Industry, CA 91745 ● Phone: (800) 793-0093 ● Fax: (626) 403-3130 ● www.dacor.com

Page 22

Installation InstructionsRenaissance® Wall Mount Range Hood with Remote BlowerModels: EHR30, EHR36, EHR42, EHR48, EHR54Part No. 103781 Rev. GAPPROVED

Page 23

1Important Information About Safety Instructions• The Important Safety Instructions and warnings in these instructions are not meant to cover all pos

Page 24 - Wiring Diagrams

Preparing for Installation ... 8Verify the Package Contents ...

Page 25

1Important Information About Safety Instructions• The Important Safety Instructions and warnings in these instructions are not meant to cover all pos

Page 26

2Important Safety Instructions• Do not install or operate this hood if it has been damaged, dropped, has damaged electrical wires or is not working p

Page 27

3General SpecificationsAll ModelsFan Speeds 4Filters Mesh type, dishwasher safeExhaust(s) 8-inchTotal Connect Load120 Vac, 60 Hz, 6.5 Amp. Max.Lights

Page 28

4DimensionsProduct SpecificationsModels EHR48, EHR54 All other models See facing page* ** ***NOTE: The exhaust duct(s) and electrical wiring can be co

Page 29 - Wall Mount Range Hood

5C11 7/8” (30.2 cm)ABProduct SpecificationsOVERALL DIMENSIONSModel A B C D***EHR3012 29 7/8” (75.9 cm)26 7/8”(68.3 cm)12 3/8”(31.4 cm)4 1/2”(11.4 cm)E

Page 30

6Planning the InstallationCabinet Layout WARNINGTo reduce the risk of personal injury caused by reaching over a hot appliance, cabinet storage space l

Page 31

7Planning the Installation WARNING• To prevent combustion by-products, smoke or odors from entering the home and to improve efficiency, tape all duct

Page 32

8Planning the InstallationPreparing for InstallationDuct Work Equivalent LengthsEQUIVALENT LENGTHS Piece Subtract Piece Subtract8” 90° elbow 7 feet 10

Page 33 - Product Specifications

9Electrical Service Installation WARNINGThe electric service to the range hood should be installed only by a licensed electrician.Install a junction b

Page 34

2Important Safety Instructions• Do not install or operate this hood if it has been damaged, dropped, has damaged electrical wires or is not working p

Page 35

10Installation Instructions WARNING• Do not install the range hood unless the electrical service provided meets the range hood specifica-tions.• Obs

Page 36 - Planning the Installation

113. Find the temporary mounting bracket in the shipping box. Put the bracket against the wall and line up the center hole with the intersection of t

Page 37

12Installation InstructionsMounting Hole LocationsHanging the Range Hood WARNINGHanging the range hood requires two people. Do not attempt to lift the

Page 38

13N2N1GndL2L1Gnd (Green)(Green)(White)(Black)(Blue)(Red)Installation InstructionsTo junction boxHood powerterminalsGroundGroundNeutralNeutralHotHotTo

Page 39

14Installation InstructionsInsulated Pipe Jumper(if necessary)GREENGREENWHITEWHITEBLACKBLACKGrounding the Hood Wiring Using an External Cold Water Pip

Page 40

15Verifying Proper Operation1. Make sure the main power switch is off.2. Turn on power at the circuit breaker panel or fuse box.3. Turn on the main

Page 41

16Wiring DiagramsHOOD LIGHTS75W, 120V EACHCONNECT TO120V, 60HZ, 15ASINGLE PHASE POWER SUPPLYCHASSISGROUNDPOWERSWITCHWIRE COLOR CODEW - WHITEB - BLUEY

Page 42

17Wiring DiagramsHOOD LIGHTS75W, 120V EACHCONNECT TO120V, 60HZ, 15ASINGLE PHASE POWER SUPPLYCHASSISGROUNDPOWERSWITCHWIRE COLOR CODEW - WHITEB - BLUEY

Page 43

Dacor ● 14425 Clark Avenue, City of Industry, CA 91745 ● Phone: (800) 793-0093 ● Fax: (626) 403-3130 ● www.dacor.com

Page 44

3General SpecificationsAll ModelsFan Speeds 4Filters Mesh type, dishwasher safeExhaust(s) 8-inchTotal Connect Load120 Vac, 60 Hz, 9 Amp. Max.(10.0 Amp

Page 45

4DimensionsProduct SpecificationsModels EH48, MH48, EH54 All other models See facing page* ** ***NOTE: The exhaust duct(s) and electrical wiring can b

Page 46

5Parts List• 2 temporary mounting brackets• Temporary mounting hardware• Hood assembly with filters (size and style varies with model)• Blower mou

Page 47

6Planning the InstallationCabinet Layout WARNINGTo reduce the risk of personal injury caused by reaching over a hot appliance, cabinet storage space l

Page 48

7Planning the Installation WARNING• To prevent combustion by-products, smoke or odors from entering the home and to improve efficiency, tape all duct

Commentaires sur ces manuels

Pas de commentaire